Ablation Catheters

Cerablate® easy / Cerablate® easy TC
Steerable RF Ablation and Mapping Catheter
with integrated Temperature Sensor

CERABLATE® easy is a steerable ablation catheter designed for radiofrequency ablation of cardiac tachyarrhythmias. With its 4mm platinum tip and its precise steering mechanism it is ideally suited both for standard and complex ablations.

Special Features:
- Superior handling characteristics
- Precise, smooth movement of the curve setting
- Excellent torque control

- Optimal curve stability
- Very good x-ray visibility
- Excellent temperature response
- Compatible with all commonly available radio frequency
  generators for cardiac arrhythmia ablation

Technical Data:
- 7F Diameter

- 4-polar
- Tip-size: 4 mm
- Pole spacing 2 mm, 1-4-1 mm or 2-5-2 mm
- Classic or Sigma curve types
- Curve diameter 30, 45 or 60 mm
- Usable length 80 cm or 110 cm
- Temperature sensor: thermistor or thermocouple

​ ​​ ​

 

Cerablate cool®
Steerable Ablation Catheter with irrigated GOLD-Tip

CERABLATE cool® is a gold-tipped 4mm irrigated radiofrequency ablation catheter. The patented design of the catheter tip contains 25 irrigation holes that provide highly efficient cooling of the electrode.

Special Features:
- Due to efficient cooling, the choice of materials used and the overall design,
  it is possible to create deeper lesions with reduced coagulation formation
  and higher efficiency 1,2.

1 Balazs T, Laczko R, Bognar E, et al: Ablation time efficiency and lesion volume – in vitro comparison of 4mm non-irrigated gold- and platinum-tip radio frequency ablation catheters. J Interv Card Electrophysiol. 2013 Jan;36(1):13-8; discussion 18.  

 2 Linhart M, LIberman I et al: Superiority of gold versus platinum irrigated tip catheter ablation of the pulmonary veins and the cavotricuspid isthmus: a randomized study comparing tip temperatures and cooling flow requirements. J Cardiovasc Electrophysiol. 2012 Jul;23(7):717-21.  

​ ​​ ​

 

Cerablate flutter®
Steerable Ablation Catheter with 8 mm GOLD-Tip

CERABLATE flutter® is especially designed for the treatment of atrial flutter. The large 8mm gold-tip allows for particularly fast and efficient lesion formation while improving patient safety due to reduced thrombus formation1,2,3.

Special Features:
- Very fast temperature measurement for greatest safety; tip electrode
  especially designed for fast and deep lesions
- Reduced coagulation formation and reduced ablation time
- Ultra-precise mapping possible due to extra small distance between first
  and second catheter pole which makes this catheter especially suitable for
  the Maximum Voltage Guided (MVG) ablation approach2,3,4.

1 Balazs T, Laczko R, Bognar E, et al: Ablation time efficiency and lesion volume – in vitro comparison of 4mm non-irrigated gold- and platinum-tip radio frequency ablation catheters. J Interv Card Electrophysiol. 2013 Jan;36(1):13-8; discussion 18.  

2 Kardos A, Foldesi C, Mihalcz A et al: Cavotricuspid Isthmus Ablation with Large-Tip Gold Alloy Versus Platinum-Iridium-Tip Electrode Catheters. Pacing Clin Electrophysiol. 2009 Mar;32 Suppl 1:S138-40.  

3 Lewalter T, Lickfett L, Weiss C, et al: “Largest Amplitude Ablation” is the Optimal Approach for Typical Atrial Flutter Ablation: A Subanalysis from the Aurum 8 Study. J Cardiovasc Electrophysiol. 2012 May;23(5):479-85

4 Deutsch K, Sledz J, Mazij M, et al: Maximum voltage gradient technique for optimization of ablation for typical atrial flutter with zero-fluoroscopy approach. Medicine (2017) 96:25(e6939)

​ ​​ ​